Featured Product
New LAUDA Integral XT 280
Highly Dynamic Thermostat for External Process Control and Reactor Chemistries from
-80 °C to 200 °C.
Calibration and adjustment with LAUDA calibration thermostats at temperatures from -40 up to 300 °C
LAUDA Calibration thermostats are the first choice when it comes to temperature stability, greatest reliability, and homogeneity during calibration and adjustment. The high performance complete solutions for individual requirements are available in the Ecoline Staredition, Proline, and Ultra models. They differ in terms of size, bath-opening, and useable depth. Thermostats, in particular, are superior to heating cabinets and metal block thermostats as the heat transfer into the heat transfer liquid is 40 to 60 times better than through the air.
| The Calibration thermostats advantages | Your benefits | |
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
|
The calibration thermostats of the LAUDA Ecoline Staredition range offer you temperature stabilities to ±0.01 K at temperatures down to -30 ºC. The RE 212 J model with its two-line display, digital interface and basic programmer is convincing. The even more user-friendly RE 312 J offers the possibility of external control for even better accuracy and the PC software LAUDA Wintherm Plus. In the heating range, the compact Proline PJ 12/PJ 12 C models reach maximum temperatures up to 300 °C. The PJL 12/PJL 12 C were designed especially for operation with the LAUDA DLK 45 through-flow cooler and reach temperatures down to -40 ºC.
LAUDA Ultra calibration thermostats offer excellent temperature stability and distribution values across a wide temperature range in the test chamber. The overflow principle ensures constant immersion depths here as well. The height of the liquid’s surface can be changed to adjust com- pletely immersed thermometers or other test objects. Thanks to its special insulation, the UB-JL range can be used with the LAUDA DLK 45 through- flow cooler down to -40 ºC.
Select up to 3 products to compare: Compare Products
Calibration thermostats Ecoline Staredition and Proline
| Technical features | RE212 J | RE312 J | |
| Select to compare: | |||
| Working temperature range* | °C | 30...200 | 30...200 |
| Temperature stability | ±K | 0.01 | 0.01 |
| Resolution of indication | °C | 0.05 | 0.05/0.01 |
| Heating power | kW | 1.3 | 1.3 |
| Cooling output at 20 °C | kW | 0.30 | 0.30 |
| Pump pressure max. | bar | 0.40 | 0.40 |
| Pump flow (pressure) max. | L/min | 17 | 17 |
| Bath volume | L | 1.9/2.1 | 1.9/2.1 |
| Bath opening/usable depth | mm | Ø 150/180 | Ø 150/180 |
| Cat. No. 115 V; 60 Hz | LCK 4879 | LCK 4880 | |
| Technical features | PJ 12 | PJ 12 C | PJL 12 | PJL 12 C | |
| Select to compare: | |||||
| Working temperature range | °C | 30...300 | 30...300 | 30...200 | 30...200 |
| Operating temperature range | °C | 0...300 | 0...300 | -40**...200 | -40**...200 |
| Temperature stability | ±K | 0.01 | 0.01 | 0.01 | 0.01 |
| Resolution of indication | °C | 0.1 | 0.1/0.01/0.001 | 0.1 | 0.1/0.01/0.001 |
| Heating power 115 V/208-220 V | kW | 1.8/3.5 | 1.8/3.5 | 1.8/3.5 | 1.8/3.5 |
| Pump pressure max | bar | 0.8 | 0.8 | 0.8 | 0.8 |
| Pump flow (pressure) max. | L/min | 25 | 25 | 25 | 25 |
| Bath volume | L | 8.5...13.5 | 8.5...13.5 | 8.5...13.5 | 8.5...13.5 |
| Bath opening/depth | mm | Ø 120/320 | Ø 120/320 | Ø 120/320 | Ø 120/320 |
| Usable depth | mm | 300 | 300 | 300 | 300 |
| Cat. No. 115 V; 60 Hz | LCB 4720 | LCB 4721 | LCB 4718 | LCB 4719 | |
| Cat. No. 208-220 V; 60 Hz | LCB 8720 | LCB 8721 | LCB 8718 | LCB 8719 | |
* Working temperature range is equal to the ACC range.
** At -40 °C in conjunction with LAUDA through-flow cooler DLK 45
Calibration thermostats Ultra UB
| Technical features | UB 20 J | UB 30 J | UB 40 J | UB 65 J | |
| Select to compare: | |||||
| Working temperature range* | °C | 45...300 | 45...300 | 45...300 | 80...300 |
| Temperature stability | ±K | 0.005…0.01 | 0.005…0.01 | 0.005…0.01 | 0.005…0.01/td> |
| Resolution of indication | °C | 0.01/0.001 | 0.01/0.001 | 0.01/0.001 | 0.01/0.001 |
| Heater power | kW | 3.0 | 3.0 | 3.0 | 3.0 |
| Pump flow max. | bar | 0.30 | 0.30 | 0.30 | 0.30 |
| Pump flow (pressure) max. | L/min | 15 | 15 | 15 | 15 |
| Bath volume | L | 15...18 | 22.5...30 | 32.5...40 | 48...54 |
| Bath opening/depth | mm | Ø 195/195 | Ø 195/320 | Ø 195/450 | Ø 215/690 |
| Usable depth | mm | 175 | 300 | 430 | 650 |
| Cat. No. 230 V; 60 Hz | LTB 236 | LTB 237 | LTB 238 | LTB 242** | |
| Technical features | UB 20 F | UB 20 JL | UB 30 JL | UB 40 JL | |
| Select to compare: | |||||
| Working temperature range | °C | 35...200 | 45...200 | 45...200 | 45...200 |
| Operating temperature range | °C | 0…200 | -40*…200 | -40*...200 | -35*...200 |
| Temperature stability | ±K | 0.005 | 0.005...0.01 0.005... | 0.005...0.01 0.005... | 0.005...0.01 0.005... |
| Resolution of indication | °C | 0.01/0.001 | 0.01/0.001 | 0.01/0.001 | 0.01/0.001 |
| Heater power | kW | 1.2 | 3.0 | 3.0 | 3.0 |
| Pump flow max | bar | 0.20 | 0.30 | 0.30 | 0.30 |
| Pump flow (pressure) max. | L/min | 12 | 15 | 15 | 15 |
| Bath volume | L | 15...18 | 15...18 | 22.5…30 | 32.5…40 |
| Bath opening/depth | mm | Ø 195/195 | Ø 195/195 | Ø 195/320 | Ø 195/450 |
| Usable depth | mm | 175 | 175 | 300 | 450 |
| Cat. No. 230 V; 60 Hz | LTB 239 | LTB 243 | LTB 244 | LTB 245 | |
* At -40 or -35 °C in conjunction with LAUDA through-flow cooler DLK 45
** 80 °C only with water
Calibration rack
| Cat. No. | Qty. samples | Ø mm | suitable for |
| UG 092 | 180 | 6,5 | UB 20 F, UB 20 J |
Rotoracks
For thermometers or temperature probes for calibration purposes, all racks
made from stainless steel, rotating and height adjustable
| Cat. No. | Qty. samples | Ø mm | height adjustable |
suitable for |
| UG 093 | 20 | 10 | Yes | UB 20 F, UB 20 J |
| UG 099 | 20 | 10 | Yes | UB 30 J |
| UG 100 | 20 | 10 | Yes | UB 40 J |
| UG 110 | 18 | 11 | Yes | RE 212 J, RE 312 J |
| UG 111 | 20 | 10 | Yes | RE 212 J, RE 312 J |
| UG 112 | 15 | 12 | Yes | PJ 12 (C), PJL 12 (C) |
Bath cover stainless steel
| Cat. No. | Description | suitable for |
| LTZ 032 | Bath cover, circular with handle | UB 20 F, J, UB 30 J, UB 40 J UB 65 J |
Platinum resistance thermometers
For use on Pt100 inputs, stainless steel
version to DIN EN 60751 (for connecting
cables except for Pt100-94), with Lemo connection socket, accuracy class A
LAUDA Digital thermometers
| Technical features | DigiCal DCM 2 | DigiCal DCS 2 |
| Measuring range °C | -200...450 | |
| Resolution °C | 200...200: 0.01 > 200: 0.1 | |
| Temperature probe | Pt100 Kl. B1/3 DIN sheath resistance probe in 4-conductor | |
| Digital output as standard | RS 232, electrically isolated, on 8-pole DIN socket | RS 232, electrically isolated, with 9-pole Sub D socket on the rear |
| Cat. No. | LMD 917 | LMD 018 (230 V; 50/60 Hz) |
| Cat. No. | LMD 818 (90-260 V; 50/60 Hz) | |