Featured Product
New LAUDA Integral XT 280
Highly Dynamic Thermostat for External Process Control and Reactor Chemistries from
-80 °C to 200 °C.
Extra powerful cooling thermostats for bath applications from -90 up to 200 °C
The new Proline Kryomats are floor-standing, low temperature thermostats suitable for a wide variety of applications. They never fail to impress through their compact design and high cooling capacities, especially at low temperatures. All Proline Kryomats are fitted with the Command remote control for easy and user-friendly operation.
The units are equipped with a pressure pump optimized for internal Extra powerful cooling thermostats for bath applications from -90 up to 200 °C LAUDA Proline Kryomats circulation adjustable from performance level five to eight. To prevent moisture in the atmosphere from condensing at low temperatures, bath bridge and bath edge heating are integrated into the design. Proline Kryomats stand out for having the latest technologies and an excellent price-performance ratio.
| The Proline Kryomats advantages | Your benefits | |
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
|
![]() |
|
|
The air-cooled Proline Kryomats have a working temperature range from -50 and -90 up to 200 °C. The models are available with bath volumes of 30 and 40 liters. The Proline SmartCool system, with its energy saving digital cooling management, ensures that the cooling output is run in accordance with the application needs. That saves up to 75 percent of energy compared to standard cooling methods.
Two different booster pumps are available as accessories especially for external applications that require a considerable increase in volume flow/ discharge pressure.
In the case of the water-cooled Proline Kryomats, the process heat is disipated with the use of facility cooling water. This largely prevents unnecessary heating of the surrounding environment. As a result of this type of cooling, even higher cooling capacities are achieved than with the aircooled units. The electronic cooling water management minimizes water consumption. The enhanced booster pumps, available as accessories, are particularly recommended for external applications where increased volume flow or greater pressures are required.
Select up to 3 products to compare: Compare Products
Proline Kryomats Air-cooled cooling thermostats
| Technical features | RP 3050 C | RP 4050 C | RP 3090 C | RP 4090 C | |
| Select to compare: | |||||
| Working temperature range* | °C | -50...200 | -50...200 | -90...200 | -90...200 |
| Temperature stability | ±K | 0.05 | 0.05 | 0.05 | 0.05 |
| Heater power | kW | 3.0 | 3.0 | 3.0 | 3.0 |
| Cooling output at 20 °C | kW | 5.0 | 5.0 | 3.0 | 3.0 |
| Pump pressure max. | bar | 0.5 | 0.5 | 0.5 | 0.5 |
| Pump flow (pressure) max. | L/min | 19 | 19 | 19 | 19 |
| Bath volume | L | 23...31 | 32...44 | 23...31 | 32...44 |
| Bath opening/depth | mm | 350x200/250 | 350x350/250 | 350x200/250 | 350x350/250 |
| Cat. No. 208 V; 3/PE; 60 Hz | - | LUK 339 | LUK 341 | LUK 345 | LUK 347 |
* Working temperature range is equal to ACC range
Proline Kryomats Water-cooled cooling thermostats
| Technical features | RP 3050 CW | RP 4050 CW | RP 3090 CW | RP 4090 CW | |
| Select to compare: | |||||
| Working temperature range* | °C | -50...200 | -50...200 | -90...200 | -90...200 |
| Temperature stability | ±K | 0.05 | 0.05 | 0.05 | 0.05 |
| Heater power | kW | 3.0 | 3.0 | 3.0 | 3.0 |
| Cooling output at 20 °C | kW | 6.0 | 6.0 | 4.0 | 4.0 |
| Pump pressure max. | bar | 0.5 | 0.5 | 0.5 | 0.5 |
| Pump flow (pressure) max. | L/min | 19 | 19 | 19 | 19 |
| Bath volume | L | 23...31 | 32...44 | 23...31 | 32...44 |
| Bath opening/depth | mm | 350x200/250 | 350x350/250 | 350x200/250 | 350x350/250 |
| Cat. No. 208 V; 3/PE; 60 Hz | - | LUK 340 | LUK 342 | LUK 346 | LUK 348 |
* Working temperature range is equal to ACC range
Interface modules
An RS 232/485 interface is integrated as a standard feature. The control head is
equipped for two interface modules to be plugged into the rear of the unit.
| Cat. No. | Description | Description |
| LRZ 913 | RS 232/485 interface | Electrically isolated, 9-pin SUB-D socket |
| LRZ 912 | Analogue module | 2 x In, 2 x Out, 0(4)…20 mA or 0…10 V |
| LRZ 915 | Contact module SUB-D | 3 x In, 3 x Out, 15-pin SUB-D |
| LRZ 914 | Contact module NAMUR | 1 x In, 1 x Out, NE 28, 2 DIN socket |
| LRZ 917 | Profibus module | Electrically isolated, 9-pin SUB-D socket |
Suitable tubings for heat transfer liquids and cooling water
Available upon request.
Booster pumps
For higher flow rates and pressure for external systems, connections M 30 x 1.5 O
| Cat. No. | Description | Temperature range | Pressure max. | Pump flow max. |
| LWZ 080 | EMP 174 | -100...150 °C | 0,9 bar | 90 L/min |
| LWZ 086 | EMP 081 | -40...150 °C | 3,2 bar | 40 L/min |
(O = outer thread)
Baskets
For notch bending test
| Cat. No. | Suitable for |
| LUZ 008 | RP 3050 C, RP 3050 CW, RP 3090 C, RP 3090 CW |
| LUZ 009 | RP 4050 C, RP 4050 CW, RP 4090 C, RP 4090 CW |
Pour point determination
Bath cover accomodates up to 16 metal beakers
| Cat. No. | Suitable for |